Skip to content

Starlark models

Models collect structured data using the existing device transports. Commands, platform selection, parsing and calculations live in external .star files. There is no embedded model registry and no dependency on Glavnoc or Godograf.

For a step-by-step authoring guide with parsing and test examples, see the models README.

CLI

Run from the repository root, or provide an absolute models directory:

go run ./cmd/cli -hostname switch.example.net -devtype huawei \
  -models-dir ./models -model uptime -use-ssh-config

Model mode always prints a JSON object. It cannot be combined with -command or -test. -question is supported as a default answer for model commands. The existing CLI's 30-second context covers connection and collection.

Server and Python

models_dir: /etc/gnetcli/models

The server also accepts --models-dir. An explicitly supplied flag overrides YAML, including --models-dir= to disable models. An empty directory setting leaves ordinary command RPCs available but disables model RPCs. Paths are relative to the process working directory, not the configuration file.

CollectModel takes host, model and optional host_params. The device type, credentials and transport follow the same resolution rules as command execution. The corresponding HTTP endpoint is POST /api/v1/collect_model:

{"host":"switch.example.net","model":"uptime","host_params":{"device":"huawei"}}

The response's json string contains a JSON object. It is deliberately not a protobuf Struct: a floating-point representation would lose nanosecond precision. HTTP clients must parse this nested string with an integer-preserving decoder.

result = await client.collect_model(
    "switch.example.net", "uptime", host_params=HostParams(device="huawei"),
)
print(result["up-time"])  # Python int, nanoseconds

Go API

runner, err := models.New("./models")
if err != nil {
    return err
}
// The caller connects and closes dev. Collect never owns the connection.
result, err := runner.Collect(ctx, dev, "huawei", "uptime")

The result is json.RawMessage; decode into integer fields or use json.Decoder.UseNumber, not map[string]any with default float64 decoding. Options include WithMaxExecutionSteps (default 1,000,000, must be positive) and WithCommandOptions (defaults applied to every executed command). Separate devices are needed for concurrent calls unless the device supports concurrent execution itself.

Writing a model

Model names match [A-Za-z0-9][A-Za-z0-9_-]*. A request for sample loads <models_dir>/sample.star:

load("re.star", "re")

def collect(device):
    output = device.execute("show version")
    return {"device-type": device.type, "version": output.strip()}

device.type is the resolved gnetcli device type. device.execute(command) returns cleaned command output as a string. Transport errors and nonzero device command status abort the model; no partial result is returned. The function collect must return a JSON-compatible dict with string keys. Integers are encoded exactly. The runner is not aware of model names, vendors or schemas.

There is currently no YANG or model-schema validation. Required fields, types, ranges and unknown fields are not checked by the runner; each model must validate its parsed values and test its result shape explicitly.

Imports are relative to the model directory, not the importing file. For example, load("lib/helpers.star", "parse"). Each collection reloads source files and has isolated globals and an import cache. There is no process-wide module cache; cyclic imports fail. Deploy coherent directory versions rather than modifying multiple live files during a collection.

Available standard modules:

  • load("re.star", "re"): re.search(pattern, text) uses Go/RE2 expressions; returns None or [whole_match, group_1, ...]. Unmatched optional groups are empty strings. Inline flags such as (?m) are supported.
  • load("time.star", "time"): time.parse_ns(value, layout, location="UTC") parses a Go time layout and optional IANA location, returning integer Unix nanoseconds. Invalid/unknown timezones and values outside nonnegative int64 nanoseconds fail. Zoneinfo is included, independent of the host installation.
  • load("json.star", "json"): Starlark's standard JSON encode/decode module.

These three import names are reserved. Models can only read .star modules inside the configured directory. Absolute paths, traversal and symlink escapes are rejected. Models have no shell, filesystem or arbitrary network builtins. Only administrators should install scripts: device.execute can issue any CLI command, and the step limit is not a memory limit or a CPU limit for native builtins. Do not put credentials or production device output in scripts/tests. Context cancellation interrupts Starlark and is passed to device execution. The server bounds connection setup to 20 seconds; collection uses the RPC context and configured default command/read timeouts.

Uptime

The supplied model supports huawei and juniper:

  • Huawei: display version and display clock. Uses the first system uptime, not subsequent board uptimes. An explicit StartupTime is preferred; absent StartupTime is derived from device clock minus uptime. StartupTime without a timezone inherits the device clock's timezone.
  • Juniper: show system uptime. Uses Current time and System booted, not Node booted, to calculate elapsed time.

Fields up-time, boot-time, current-datetime are nonnegative integer nanoseconds. The latter two are Unix timestamps. Device clocks are never replaced with the collector's clock. Explicit numeric UTC offsets (including negative ones) take precedence over timezone labels; UTC/GMT/Z and MSK are supported. Unsupported device types, unknown zones, missing data and negative intervals fail. Huawei uptime rounded to minutes can differ from clock minus explicit StartupTime.

Testing and protobuf generation

Tests execute real Starlark using Go testing/require, fake command results, and mock SSH dialogs. Run go test ./pkg/models/....

Use make proto with the project Docker image. Without Docker, the same target can use local generators:

make proto proto_runner=